☰
Home
Products
Analytical System
Semi-prep/Prep System
Specific Analytical System
Pump
Detector
Autosampler
Column Oven
Data system
Data system
Others
Analytical Colum
Specific Columns
Semi-prep / Prep Column
Applications
Application Classification
Food
Drink
Agricultural products
Feed
Condiments and others
Chemical
Chemical materials
Daily necessities
Pesticide
Other
Pharmaceutical
Traditional Chinese medicine
Western medicine
Veterinary drugs
Biopharmaceutical
Environmental
Atmosphere
Soil
Water resources
Services & Support
About Us
Contact Us
Questionnaire
Chinese
APPLICATIONS CLASSIFICATION
icon08
Home
>
Applications
>
Application Classification
Food
Drink
Agricultural products
Feed
Condiments and others
Chemical
Chemical materials
Daily necessities
Pesticide
Other
Pharmaceutical
Traditional Chinese medicine
Western medicine
Veterinary drugs
Biopharmaceutical
Environmental
Atmosphere
Soil
Water resources
P-phenylenediamine aniline benzidine p-toluidine p-chloroaniline
2021-05-07
Mobile phase: mobile phase A: methanol, mobile phase B: 10 mmol/L pH=7 phosphate buffer Column: Hypersil ODS2 5 µm 4.6×250 mm Flow rate: 1.0 mL/min Detection: Ex473 nm, Em535 nm Injection volume: 10 µL Column temperature: 35 ℃ 1. p-phenylenediamine 2...
more
Putrescine Cadaverine Spermidine Spermine Histamine
2021-05-07
Mobile phase: Mobile phase A: Acetonitrile Mobile phase B: 20mmol/L ammonium acetate solution Column: SinoChrom ODS-BP 5µm 4.6×150mm Flow rate: 1.0mL/min Detection: Ex473nm, Em535nm Injection volume: 10µL Column temperature: 35℃ 1- putrescine; 2-cada...
more
16 kinds of polycyclic aromatic hydrocarbons (PAHs)
2021-05-07
Mobile phase: A: acetonitrile; B: water Column: Supersil ODS2 5 µm4.6×250 mm Flow rate: 1.0 mL/min Detection: 220 nm Injection volume: 10 µL Column temperature: 30 ℃
more
Fluorescein isothiocyanate
2021-05-07
Mobile phase: methanol/water=60/40 Column: Hypersil ODS2 5 µm 4.6×250 mm Flow rate: 1.0 mL/min Detection: 234 nm Injection volume: 2 µL Column temperature: 30 ℃
more
Methomyl oxime
2021-05-07
Mobile phase: methanol: water=50:50 Column: SinoChrom ODS-BP 5 µm 4.6×250 mm Flow rate: 1.0 mL/min Detection wavelength: 235 nm Injection volume: 10 µL Column temperature: 30 ℃ 1- methomyl oxime
more
Fluflumuron
2021-05-07
Mobile phase: acetonitrile: 0.1% formic acid = 2:98 Column: SinoChrom ODS-BP 5 µm 4.6×250 mm Flow rate: 1.0 mL/min Detection: RI Injection volume: 10 µL Column temperature: 30 ℃ 1-flufenuron
more
Glyphosate content analysis
2021-05-07
more
1
2
3
4
5
6
7
8